Calibrate and Update Xhorse Condor II

 This is a guide on how to setup, calibrate & test, update Xhorse Condor XC-Mini Plus II key cutting machine for the first time. Read this article carefully to learn.

 

How to prepare Condor II?

  1. Plug in device, and power it up.
  2. Remove brands & loosen milling bolts with provided hex wrench, then insert probe into left-side clamp, cutter into right-side.
  3. Align probe and cutter at visually even height once tightened.
  4. Fully inset M5 clamp from right to left into clamp vice, secure in place.

set up Xhorse Condor II 1

set up Xhorse Condor II 2

How to setup & bind Condor II?

  1. Select preferred language, accept privacy policy and continue.
  2. Connect to WiFi
  3. Log in Xhorse account to get security code, press “OK” to bind device.

Device activation success.

set up Xhorse Condor II 3

set up Xhorse Condor II 4

How to calibrate & test Condor II?

  1. Setting >> Device calibration >> Height calibration >> Start

Tip: install M5 clamp then select A position(side A is upwards) and tighten left, don’t insert key blank.

calibrate Xhorse Condor II 1

calibrate Xhorse Condor II 2

  1. Once complete begin “Cutting Calibration”, insert HO01 test key, align with last mark, flat and secured into place before starting.

Use debris brush to remove all metal shavings from the clamp and key surfaces then continue.

calibrate Xhorse Condor II 3

  1. Clamp Deviation >> M5-A clamp, insert and align HON66 test key to fifth and final marker. Press “Start”.

When completed, move on to side-B and place key blank into the channel, sitting atop of the clamp surface before tightening.

calibrate Xhorse Condor II 4

calibrate Xhorse Condor II 5

Tip: Incorrect insertion will result in an error code and red flashing hazard to signal need of adjustment. Simply correct and continue.

 

  1. Begin “Motor Measurement”. Run each test once to ensure proper function and movement of all rotors, for all 4 angles off motion.

calibrate Xhorse Condor II 6

 

  1. In order to test the “Electrical Conductivity”, use a key blank to ground the probe or cutter to the clamp. Green circle means good connection.

calibrate Xhorse Condor II 7

 

How to finish settings & upgrade?

  1. Select “Cutting Setting” to see available adjustments or setup options available to make the Xhorse Condor 2 your perfect cutting machine.
  2. Go to Update and install any every time they are available to ensure perfect function.

Once updated, check out the fully-packed, ready to work Key and Vehicle Lists.

update Xhorse Condor II 1

update Xhorse Condor II 2

www.vvdishop.com

https://www.vvdishop.com/service/set-up-calibrate-and-update-xhorse-condor-ii.html

 


上の画像に書かれている文字を入力して下さい
 
<ご注意>
書き込まれた内容は公開され、ブログの持ち主だけが削除できます。
< 2024年11月 >
S M T W T F S
          1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30
カテゴリ
QRコード
QRCODE

アクセスカウンタ
読者登録
メールアドレスを入力して登録する事で、このブログの新着エントリーをメールでお届けいたします。解除は→こちら
現在の読者数 0人
プロフィール
jtac
jtac